Study reports significant reduction in postsurgical scar depth following DC microcurrent stimulation

· Medical Xpress

by Center For Pain And Stress Research Ltd

edited by Lisa Lock, reviewed by Robert Egan

Lisa Lock

Scientific Editor

Meet our editorial team
Behind our editorial process

Robert Egan

Senior Editor

Meet our editorial team
Behind our editorial process Editors' notes

This article has been reviewed according to Science X's editorial process and policies. Editors have highlighted the following attributes while ensuring the content's credibility:

fact-checked

proofread

The GIST Add as preferred source


Ultrasound of DC microcurrent applied pre-and post-treatment, as measured by 3D 17 MHz volumetric linear probe. Credit: Journal of Bodywork and Movement Therapies (2026). DOI: 10.1016/j.jbmt.2026.07.039

A new pilot study reports that direct-current (DC) microcurrent stimulation was associated with a statistically significant reduction in measured postsurgical scar depth immediately following a single treatment. The article, "Effects of DC microcurrent stimulation on scar remodeling and tissue recovery," has been accepted for publication in the Journal of Bodywork and Movement Therapies.

The prospective, nonrandomized cohort study included 17 patients with surgically induced scars. Researchers measured scar depth at the same anatomical locations immediately before and after treatment using a 17 MHz three-dimensional volumetric ultrasound probe.

Each participant received one DC microcurrent treatment using two Dolphin Neurostim devices. Stimulation was applied bilaterally along the scar for 30 seconds per point at approximately half-inch (1.3 cm) intervals, using opposing polarities. Treatment sessions lasted approximately 15–20 minutes.

Measured change after one session

Mean scar depth decreased by 0.447 mm, representing an average reduction of 23.8%. The change was statistically significant, with a 95% confidence interval of 0.264 to 0.630 mm and p < 0.001.

The authors state that, to their knowledge, the study represents the first report of DC microcurrent therapy producing a measurable reduction in the physical size of scar cicatrix. The study used high-resolution ultrasound to provide an objective structural measure rather than relying solely on visual assessment or patient-reported change.

All participants also spontaneously reported improvements in pain and range of motion. However, these outcomes were not formally measured as part of the study and therefore require further investigation.

Possible clinical effects remain untested

The authors propose that changes in scar morphology may have implications for tissue mobility, fascial glide and rehabilitation, but these potential clinical effects remain hypotheses that require confirmation in controlled trials. The manuscript notes that thickened or tethered scars can restrict fascial glide and alter biomechanics, while reduced fibrosis or tissue softening could potentially improve mobility and reduce mechanical irritation.

"This study introduces an objective imaging approach for evaluating scar response to DC microcurrent stimulation," said Dr. R. Gokal, corresponding author. "The findings are encouraging and support further investigation using larger controlled studies and longer-term follow-up."

The researchers emphasize that the study was preliminary. It included only 17 patients, had no control or placebo group, and measured outcomes immediately after a single treatment. The study therefore does not establish whether the observed changes are sustained over time or whether repeated treatment would produce similar or greater effects.

The authors conclude that high-resolution ultrasound may provide clinicians and researchers with a useful objective method for studying structural changes in scar tissue following noninvasive interventions.

More information

R. Gokal et al, Effects of DC microcurrent stimulation on scar remodeling and tissue recovery, Journal of Bodywork and Movement Therapies (2026). DOI: 10.1016/j.jbmt.2026.07.039

Key medical concepts

Pain

Clinical categories

Physiatry Provided by Center For Pain And Stress Research Ltd Who's behind this story?

Lisa Lock

BA art history, MA material culture. Former museum editor, paramedic, and transplant coordinator. Editing for Science X since 2021. Full profile →

Robert Egan

Bachelor's in mathematical biology, Master's in creative writing. Well-traveled with unique perspectives on science and language. Full profile →

Citation: Study reports significant reduction in postsurgical scar depth following DC microcurrent stimulation (2026, August 15) retrieved 15 August 2026 from https://medicalxpress.com/news/2026-08-significant-reduction-postsurgical-scar-depth.html This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.